Crypto Minotaur PDU FUSED | 24× C-19 Outlets

92.4kW of Brute Force Power

Input Fuse Protection

3 x 150 amp input fuses provide superior protection to critical loads, adding an additional over-current mitigation layer between your panel and the output breakers of the PDU. With fuses installed the Minotaur is 200kAIC rated.

THE HIGHEST DENSITY PDU ON THE PLANET!

The Crypto Minotaur is a versatile 0U, 384 amp PDU designed specifically for crypto mining applications. 3 x 150A input fuses, 12 x 50 amp breakers, and 24 x C-19 outlets give the Minotaur a powerful punch.

Unparalleled Density

The Crypto Minotaur is packed with 24 x C-19 outlets that can be loaded with 20 amps each. Equipped with 12 banks of 50 amp switched circuit breakers, de-rated to 40 amps, the Minotaur can power up to 384 amps of single-phase load. Specially made splitter cables double the Minotaur’s outlet capacity and streamline the installation of S-19 and other dual-input miners.

ENCLOSURE SPECIFICATIONS
Enclosure MaterialAluminum/Steel
Enclosure Size54" x 6" X 4"
Enclosure Style0U Vertical Mount
INPUT SPECIFICATIONS
Frequency50/60Hz
Input Voltage240/415VAC Three Phase WYE
PhaseThree Phase WYE (line, line, line, neutral, ground)
Total Watts92,160 Watts (includes derations)
Total Current384 Amps of Single Phase Load, fed with 128 Amp 3 Phase (includes derations)
Input ConnectorHardwire Terminal (Lines up to 2/0, N & G up to 350MCM)
Input Protection3 x 150A Fuses (200kAIC rated)
OUTPUT SPECIFICATIONS
Output Banking Scheme1 Breaker per 2 x C-19 Outlets
Output Circuit Protection12 x 50A Switched Circuit Breakers
Output Connectors24 x C-19 Outlets (splitter power cables available for S17 and S19 miners)
Output PhaseSingle Phase (line, neutral, ground)
Output Voltage240VAC Single Phase
PRODUCT DETAILS
ComplianceUL 62368-1:2014 & CSA C22.2#62368-1:2014
Operating Temperature0C - 60C
kAIC Rating200kAIC
Country of ManufactureUSA
Drawing
Do You Need an Input Fused or Non-Fused Minotaur?

The differences are quite simple. The fused unit has 3 x 150 Amp fuses on the input of the unit. The standard unit does not. Both units have the same output circuit breakers for protection and the same number of outlets and power capacity.

Having fuses on the input provides two major benefits: expanded input protection, and a much higher kAIC rating. The kAIC rating, or interrupting current rating, is the amount of current that can pass through a component without it catching on fire. If a breaker’s kAIC rating is too low for the connected load, it may not protect the circuit from damage if overloaded — a potential fire risk.

Typical PDUs range from 5,000 to 10,000 amps of interrupted current, which works for most loads. Some crypto mines, however, concentrate large power capacity in close proximity and require higher kAIC ratings. By adding input fuses, the FUSED Minotaur brings the kAIC rating to over 200,000 amps — far exceeding even the highest requirement.

In summary: if you do not require more than a 10,000 amp interrupting current rating and do not want an extra layer of input protection, the standard Minotaur will work perfectly. If you have a higher-than-standard kAIC requirement, the Fused Minotaur is the way to go.