The Vanpow Series is a one-phase, double-conversion, On-Line Uninterrupted Power Supply (UPS) designed to address unplanned downtime and high costs in the back office, server rooms, and data center environments. With a power factor rating of 0.9, an attached power factor correction (PFC) system, and a double-conversion topology, the Vanpow series UPS provides a pure, efficient, and continuous sinewave output voltage without any fluctuations. The system is available in rack-tower design and capacities up to 10K VA to meet most business, IT, and telecommunication equipment needs. For additional runtime, external battery packs can be supplied.
| UPS | |||||||||
| Model | PSR 1000 | PSR 1500 | PSR 2000 | PSR 3000 | PSR 2000 (2U+2U) | PSR 3000 (2U+2U) | PSR 6000 | PSR 10000 | |
| Capacity (VA) | 1000 | 1500 | 2000 | 3000 | 2000 | 3000 | 6000 | 10K | |
| Capacity (Watts) | 900 | 1350 | 1800 | 2700 | 1800 | 2700 | 5400 | 9K | |
| Form | Tower or Rack | ||||||||
| Phase | Single Phase | ||||||||
| Energy Saving | Yes - ECO mode Efficiency > 94% | ||||||||
| INPUT | |||||||||
| Voltage | 100 / 110 / 115 / 120 / 127 / 208 / 220 / 230 / 240 Vac | 208 / 220 / 230 / 240 Vac | |||||||
| Voltage Range | 110 Vac | 60 ~ 144 Vac < 25% Load 70 ~ 144 Vac < 50% Load 80 ~ 144 Vac < 75% Load 90 ~ 144 Vac < 100% Load | 120 ~ 276 Vac < 25% Load 140 ~ 276 Vac < 50% Load 160 ~ 276 Vac < 75% Load 180 ~ 276 Vac < 100% Load | ||||||
| 220 Vac | 120 ~ 276 Vac < 25% Load 140 ~ 276 Vac < 50% Load 160 ~ 276 Vac < 75% Load 180 ~ 276 Vac < 100% Load | ||||||||
| Frequency Range | 50 / 60 Hz (Auto Sensing) | ||||||||
| Power Factor | > 0.97 | ||||||||
| Cold Start | Yes | ||||||||
| OUTPUT | |||||||||
| Rated Power Factor | 0.9 | ||||||||
| Waveform | Pure Sine Wave | ||||||||
| Voltage | 100 / 110 / 115 / 120 / 127 / 208 / 220 / 230 / 240 Vac ± 2% | 208 / 220 / 230 / 240 Vac ± 2% | |||||||
| Frequency | 50 / 60 Hz ± 0.25 Hz | ||||||||
| Transfer Time | 0 ms | ||||||||
| Harmonic Distortion | ≤ 2.5% THD at Linear Load | ≤ 3% THD at Linear Load | |||||||
| Crest Factor | 3 : 1 | ||||||||
| EPO Function | Option | ||||||||
| PROTECTION | |||||||||
| Overload | Line Mode | 105% - 120% for 30 seconds 121% - 150% for 10 seconds | |||||||
| Battery Mode | 101% - 109% for 10 seconds 110% - 120% for 3 seconds | ||||||||
| Surge Protection | IEC 61000-4-5 Level 3 | ||||||||
| Bypass | Internal Bypass (Automatic and Manual) | ||||||||
| Short Circuit Protection | UPS Output Cut Off Immediately | ||||||||
| BATTERY | |||||||||
| Model | PSB-1000 | PSB-1500 | PSB 2000 | PSB 3000 | PSB 2000 (2U+2U) | PSB 3000 (2U+2U) | PSB-6000 | PSB-10000 | |
| Type | 12V 7Ah | 12V 7Ah | 12V 7Ah | 12V 9Ah | 12V 7Ah | 12V 7Ah | 12V 7Ah | 12V 9Ah | |
| Quantity | 3 | 4 | 6 | 6 | 6 | 8 | 20 | 20 | |
| Sealed, Maintenance Free | YES | ||||||||
| Typical Recharge Time | 4 Hr to 90% | ||||||||
| External Battery Module | Option | ||||||||
| External Battery Connector | Option | ||||||||
| MANAGEMENT | |||||||||
| Indicator | LCD Control Panel | ||||||||
| Communication Port | RS232, USB (B-type) | ||||||||
| SNMP Slot | Option | ||||||||
| Audible Alarms | YES | ||||||||
| PHYSICAL | |||||||||
| Power Module | Dimensions (WxDxH) (In) | 16.9 x 16.8 x 3.3 | 16.9 x 19.9 x 3.3 | 16.9 x 25 x 3.3 | 16.9 x 16.8 x 3.3 | 16.9 x 23.5 x 5.2 (3U) | 16.9 x 25.9 x 5.2 | ||
| Weights (Lbs) | 36 | 39.5 | 65.7 | 72 | 22.3 | 44.1 | 55.1 | ||
| Shipping Dimensions (WxDxH) (In) | 21.5 x 21.7 x 8.1 | 21.7 x 24.5 x 8.7 | 21.7 x 29.5 x 8.7 | 21.5 x 21.7 x 8.1 | 22.1 x 29.2 x 10.8 | 22.3 x 31.7 x 8.2 | |||
| Weights (Kgs) | 42.8 | 46.3 | 75 | 80.7 | 29.1 | 53 | 69 | ||
* While 208V output, capacity will derated to 90%
* Specifications are subject to change without further notice
* Specifications are for reference, actual information should be based on real product
| UPS | |||||||
| Model | PST-1000 | PST-1500 | PST-2000 | PST-3000 | PST-6000 | PST-10000 | |
| Capacity (VA) | 1000 | 1500 | 2000 | 3000 | 6000 | 10000 | |
| Capacity (Watts) | 900 | 1350 | 1800 | 2700 | 5400 | 9000 | |
| Form | Tower | ||||||
| Phase | Single Phase | ||||||
| Energy Saving | Yes - ECO mode Efficiency > 94% | ||||||
| INPUT | |||||||
| Voltage | 100 / 110 / 115 / 120 / 127 or 208 / 220 / 230 / 240 Vac | 208 / 220 / 230 / 240 Vac | |||||
| Voltage Range | 110 Vac | 60 ~ 144 Vac < 25% Load 70 ~ 144 Vac < 50% Load 80 ~ 144 Vac < 75% Load 90 ~ 144 Vac < 100% Load | 120 ~ 276 Vac < 25% Load 140 ~ 276 Vac < 50% Load 160 ~ 276 Vac < 75% Load 180 ~ 276 Vac < 100% Load | ||||
| 220 Vac | 120 ~ 276 Vac < 25% Load 140 ~ 276 Vac < 50% Load 160 ~ 276 Vac < 75% Load 180 ~ 276 Vac < 100% Load | ||||||
| Frequency Range | 50 / 60 Hz (Auto Sensing) | ||||||
| Power Factor | > 0.97 | ||||||
| Cold Start | Yes | ||||||
| OUTPUT | |||||||
| Rated Power Factor | 0.9 | ||||||
| Waveform | Pure Sine Wave | ||||||
| Voltage | 100 / 110 / 115 / 120 / 127 or 208 / 220 / 230 / 240 Vac ± 2% | 208 / 220 / 230 / 240 Vac ± 2% | |||||
| Frequency | 50 / 60 Hz ± 0.25 Hz | ||||||
| Transfer Time | 0 ms | ||||||
| Harmonic Distortion | ≤ 2.5% THD at Linear Load | ≤ 3% THD at Linear Load | |||||
| Crest Factor | 3 : 1 | ||||||
| EPO Function | Yes | ||||||
| PROTECTION | |||||||
| Overload | Line Mode | 105% - 120% for 30 seconds 121% - 150% for 10 seconds | |||||
| Battery Mode | 101% - 109% for 10 seconds 110% - 120% for 3 seconds | ||||||
| Surge Protection | IEC 61000-4-5 Level 3 | ||||||
| Bypass | Internal Bypass (Automatic and Manual) | ||||||
| Short Circuit Protection | UPS Output Cut Off Immediately | ||||||
| BATTERY | |||||||
| Model | PSB-1000 | PSB-1500 | PSB-2000 | PSB-3000 | PSB-6000 | PSB-10K | |
| Type | 12V 7Ah | 12V 7Ah | 12V 7Ah | 12V 7Ah | 12V 7Ah | 12V 9Ah | |
| Quantity | 3 | 4 | 6 | 8 | 20 | 20 | |
| Sealed, Maintenance Free | YES | ||||||
| Typical Recharge Time | 4 Hr to 90% | ||||||
| External Battery Module | Option | ||||||
| External Battery Connector | Option | ||||||
| MANAGEMENT | |||||||
| Indicator | LCD Control Panel | ||||||
| Communication Port | RS232, USB (B-type) | ||||||
| SNMP Slot | Option | ||||||
| Audible Alarms | YES | ||||||
| PHYSICAL | |||||||
| Power Module | Dimensions (WxDxH) (In) | 6 x 16.6 x 9.3 | 6 x 19.7 x 9.5 | 7.9 x 16.6 x 14.1 | 10.2 x 23.3 x 22.5 | 10.2 x 27.2 x 23.1 | |
| Weights (Lbs) | 33.5 | 43 | 64 | 66.4 | 190 | 213 | |
| Shipping Dimensions (WxDxH) (In) | 11.1 x 21.5 x 14 | 11.1 x 24.7 x 14 | 13.4 x 20.7 x 19.1 | 16.4 x 30 x 31.5 | 16.1 x 34 x 31.5 | ||
| Weights (Lbs) | 38.4 | 47 | 70 | 72.5 | 206 | 247 | |
* While 208V output, capacity will derated to 90%
* Specifications are subject to change without further notice
* Specifications are for reference, actual information should be based on real product
All UPSs, standard or custom, come with a full 2-year warranty on parts and labor. Well Bilt Power will, at its discretion, repair or replace any product found to be defective. Phone support is included during the 2-year warranty period.